Home · Guides

South-facing or east-west roof: self-consumption and battery

Updated 13 Oct 2026 · KilowattTally

An east-west roof produces less than a south-facing roof with the same power, but it spreads production over more hours: more in the morning and evening, less at midday. We calculated what this means for self-consumption and for the battery with PVGIS hourly series for Kassel [4] and the BDEW standard load profile [1].

Production on the two roofs

With PVGIS data for the year 2005, 1 kWp produces 981 kWh in a year with modules facing south tilted at 35°, and 811 kWh with half the modules facing east and half facing west tilted at 15° [4]. On this east-west roof, production is therefore about 17% lower.

Same house, 6 kWp

A house using 4,500 kWh in a year, 6 kWp:

Orientation Production in a year Self-consumption without battery Self-sufficiency without battery Self-sufficiency with 5 kWh Where the curve flattens
South, 981 kWh/kWp 5,886 kWh 28% 37% 64% 6 to 8 kWh
East-west, 811 kWh/kWp 4,866 kWh 35% 38% 61% 5 to 7 kWh

Without a battery, east-west covers almost the same share of consumption while producing less: more of its production falls in the hours when the house is using energy. With a battery, south catches up, because it has more surplus to shift to the evening.

Same house, 10 kWp

Orientation Production in a year Self-consumption without battery Self-sufficiency without battery Self-sufficiency with 5 kWh Where the curve flattens
South, 981 kWh/kWp 9,810 kWh 19% 41% 71% 7 to 9 kWh
East-west, 811 kWh/kWp 8,110 kWh 23% 41% 69% 6 to 7 kWh

With a system that is large compared with consumption, self-sufficiency without a battery is the same for both orientations, and the east-west curve flattens sooner.

Only the shape of the day

To separate the effect of the shape from that of the quantity, we redid the 6 kWp case giving east-west the same yield per kWp as south, 981 kWh/kWp: self-sufficiency without a battery is 39% against 37% for south, and with 5 kWh it is 64% for both. The shape of the day matters mostly without a battery; with a battery, how much energy is produced matters more.

Try it with your data

The calculator uses the same two shapes and your yield per kWp: a south-east or south-west roof lies between the two, and the closer of the two gives an indication, not a measurement. Different tilts and shading change the yield per kWp, which PVGIS estimates for your address [4].

Sources

  1. Repräsentative Profile BDEW H25, G25, L25, P25, S25 (Veröffentlichung) — BDEW Bundesverband der Energie- und Wasserwirtschaft, retrieved 13 Oct 2026
  2. PVGIS 5.3, serie orarie (seriescalc), banca dati PVGIS-SARAH3 — Commissione europea, Joint Research Centre (JRC), retrieved 13 Oct 2026